Á¦Ç°Á¤º¸
°í°´¼¾ÅÍ
ÀÚÁÖ¹¯´ÂÁú¹® ä¿ë°ø°í
»ç¿ë¼³¸í¼­ A/SÁ¢¼ö
½ÇÇè±âÀÚÀç(ÃÊÀÚ·ù) A~K Ȩ > Á¦Ç°Á¤º¸ > ½ÇÇè±âÀÚÀç(ÃÊÀÚ·ù) A~K > Cell Biology : ¼¼Æ÷»ý¹°ÇÐ > Cell Culture System : ¼¼Æ÷¹è¾ç ÀåÄ¡

ÀÚµ¿ ¼ÒÇü ¼¼Æ÷¹è¾ç Bioreactor, 250 / 500 / 1000 / 3000 ml

Automatic Cell Optimizer System(R)

°¡°Ý : °ßÀû°¡
Á¦Á¶»ç : WHEATON

¸ðµ¨¼±Åà : ÃÑ (7)°³ÀÇ ¸ðµ¨ÀÌ µî·ÏµÇ¾î ÀÖ½À´Ï´Ù.
Àüü¸ðµ¨ ¹× »ç¾çº¸±â

¸ñ·Ïº¸±â
Á¦Ç°»ó¼¼¼³¸í
* Complete, small volume Cell Culture Bioreactor Set
* The system provides a quick and accurate determination of optimum
environmental cell growth parameters.

Special Features for Control Tower & Supprot Unit
* The Control Tower(R) digital control system is a versatile and compact system for
mammalian cell culture, insect cell culture and fermentation.
* The system provides bench scale monitoring and control of operation parameters.
¤ý Monitor and Control up to 8 operation parameters
¤ý Monitor and Control parameters in multiple vessels
¤ý Network up to 32 Control Tower(R) units
* The Support Unit adds automated reagent pumping, gas mixing, and
heatingcapabilities to support the Control Tower(R) in maintaining bioreactors and
fermentors.
¤ý Modular design allows for any combication of pumps, gas mizing and heating control
¤ý Peristatic pump module for automatic addition of liquid acid, base, antifoam,
or nutrients, with or without heater option.
¤ý 4 gas mixing module for cell culture(air, O2, CO2, N2, gas) : Flow rate 0~500 cc/min

Ư¡ (Features)
* ¼¼Æ÷ ¹è¾ç¼ºÀåÀ» À§ÇÑ ÃÖÀûÀÇ È¯°æ¿ä¼Ò¸¦ ½Å¼Ó Á¤È®ÇÏ°Ô Á¶¼ºÇϰí ÃøÁ¤ÇÏ´Â ÀüÀÚµ¿ ¼ÒÇü ¼¼Æ÷ ¹è¾ç±â.
* Àû¿ëºÐ¾ß (Main Areas of Use) :
¤ý °¢Á¾ ¼¼Æ÷ ¹è¾ç / Cell Culture Process Optimization
¤ý °ïÃæ ¼¼Æ÷ ¹è¾ç ±â¼ú / Insect Cell Culture Techniques
¤ý ¹ÙÀÌ·¯½º °¨¿° ¿¬±¸ / Viral Infection Studies
¤ý ÇÏÀ̺긮µµ¸¶ ¼¼Æ÷ ¹è¾ç ¹æ¹ý / Hybridoma Cell Culture Methods
* Cell Optimizer System complete ÀÇ ±¸¼º°ú ±â´É
(1) 4±¸ Spinner flask : 1 Lit. ¶Ç´Â 3 Lit.
(2) Control Tower(R) : pH/DO/temp. Microprocessors Control, 2-Line LCD Display, Culture & Fermentation
(¹è¾ç/¹ßÈ¿)¿ëÀ¸·Î º»¡°Cell Optimizer System¡±ÀÌ¿ÜÀÇ Å¸ ±âÁ¾¿¡µµ ȣȯ »ç¿ëµÊ.
Size 16.5¡¿22.8¡¿h38.7 cm, 4.5 kg
(3) Support Unit : Pumping / 4 Gases (Air, O2, CO2 and N2)°ø±Þ. 1¡¿Base, 1¡¿Pump/Heater Module & 1¡¿4
Gas Mixing Module (Flow Rate 0~500cc/min.) Support unitÀº ±âº»ÀÌ Modular±â´ÉÀ¸·Î
1-Base unit¿¡ Pump/heater¸ðµâ°ú Gas mixing¸ðµâÀ» ÀÓÀÇ·Î MoudularÈ­ÇÏ¿© ±â´É°ú
¼º´ÉÀ» È®ÀåÇÒ ¼ö ÀÖÀ½. Size 16.5¡¿16.5¡¿h28 cm
(4) Magnetic Stirrer : ±³¹Ý ¼Óµµ Á¶Á¤, 5 ~ 100 rpm, Size 20.3¡¿20.3¡¿h11.4 cm
(5) 3¡¿Probes & Cable : pH, DO & Temperature¿ë
(6) ±âŸ Heating Pad (125 W), Filter Unit ¹× 1 Liter Storage Bottle °¢ 1°³

±Ô°Ý (Specifications)
* Electrical Requirements : 220V, 60 Hz, 1000 W
* Temperature Probe : 100 Ohm RTD
* Dissolved Oxygen Probe : Polarographic Ingold, 12mm
* pH Probe : Pressurized, Gel Filled, Ingold, 12 mm

ÁÖ¹® (Ordering)
WH.W350000.C 250 ml Cell Optimizer System complete
WH.W350010.C 500 ml Cell Optimizer System complete
WH.W350020.C 1 Lit. Cell Optimizer System complete
WH.W350030.C 3 Lit. Cell Optimizer System complete

Optional Accessories
WH.I057459 Cold Finger (1)
* For 1 or 3 Lit. Cellstir(R)
* 316L Stainless steel

WH.I057501 Sampler with plug valve, 30.5cm (2)
* For the 1 or 3 Lit. Celstir(R)
* 316L Stainless steel
* SamplingÇÏ´Â µ¿¾È Áß¼ºÀ» À¯Áö½ÃÄÑÁÖ´Â Plug valve°¡ ÇÔ²² °ø±ÞµÊ.

WH.I057599 Heating pad for Cell Optimizer
* 12.7¡¿12.7mm, 125 WÀÇ Heating Pad¸¦ Support Unit¿¡ ¿¬°á,
Control Tower(R)·Î Á¶ÀýÇÔ.

¡Ø ±â´É È®Àå/Networking, Áß¾ÓÅëÁ¦ Control ¹× Data °ü¸®(Option) :¡°BIOPRO PC minitor & control software¡±
(µÚ¿¡ ¼³¸íµÇ¾î ÀÖÀ½)¸¦ »ç¿ëÇϸé, Control Tower(R)¸¦ 32°³±îÁö Networking ÇÒ ¼ö ÀÖÀ¸¹Ç·Î ÀÌ¿¡ ÁØÇÏ´Â Units
¸¸Å­ÀÇ¡°Cell Optimizer System¡±À» NetworkingÇÏ¿© Áß¾ÓÅëÁ¦Á¶ÀýÀº ¹°·Ð ÃÖ»óÀÇ Data °ü¸®¸¦ ÇÒ ¼ö ÀÖ´Ù.
¸ðµ¨ ¹× »ç¾ç
Cat. No. ¸ðµ¨¸í ´Ü À§ °¡ °Ý ¼ö·® ¼± ÅÃ
WH.I057459 Coldfinger, option, , 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
WH.I057501 Sampler, dip w/plu., , 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
WH.I057599 Heating pad, for cell optimizer, 220-240vac, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
WH.W350000.C Cell optimizer system, 250ml, 230v, , 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
WH.W350010.C Cell optimizer system, 500ml, 230v, , 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
WH.W350020.C Cell optimizer system, il, 230v, , 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
WH.W350030.C Cell optimizer system, 3l, 230v, , 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ