ÀüÀÚµ¿ CO2 ÀÎÅ¥º£ÀÌÅÍ, ¿¡¾î ÀÚÄÏ, Á÷Á¢ °¡¿­ ¹æ½Ä, Microcomputer-Based Control Systems, HEPA Filter System

Air-jacketed Automatic CO2 Incubators, DH AutoFlow 5500, 188L, Direct Heat, 18~55¡É,0~20% CO2

°¡°Ý : °ßÀû°¡
Á¦Á¶»ç : Nuaire

¸ðµ¨¼±Åà : ÃÑ (2)°³ÀÇ ¸ðµ¨ÀÌ µî·ÏµÇ¾î ÀÖ½À´Ï´Ù.
Àüü¸ðµ¨ ¹× »ç¾çº¸±â

¸ñ·Ïº¸±â
Á¦Ç°»ó¼¼¼³¸í
* Origin : Made in USA (¹Ì±¹)
* NuAire Quality Statements (ǰÁú º¸Àå ÀÎÁõ) :
     ISO 9001:2000 Certificate (ǰÁú°æ¿µ½Ã½ºÅÛ ±¹Á¦±Ô°Ý ÀÎÁõ)
     ISO 13485 Certificate (ÀÇ·á±â±â ÀÎÁõ)

* The NuAire Incubator Control Electronics(N.I.C.E. Electronics)
* Accurate Infrared CO2 Control System
* Class 100 Air Flow Within the Chamber
* Fast Recovery Time
* Continuous Humidity Supply System


Application/»ç¿ëºÐ¾ß
* ¸ðµç ¼¼Æ÷ ¹× Á¶Á÷ ¹è¾ç °ü·Ã ¿¬±¸
* Storage and Preservation of Embryos, Gametes and Animal Tissue Cell Cultures at on near
   body Temperature.
* in vitro Fertilization, Genetic Disease, Cancer Research etc.
* Microbial Organism (Mycoplasma, Chlamydia etc.) Control

Features/Ư¡
* The NuAire Incubator Control Electronics(N.I.C.E. Electronics) : state-of-the-art Microprocessor´Â ¼¼Æ÷
   ¹è¾çÀÇ ÃÖÀûÀÇ Á¶°ÇÀ» Á¦°øÇϱâ À§ÇÑ Ã¨¹ö ³» ȯ°æÀ» Á¤È®ÇÏ°Ô Á¶ÀýÇÏ´Â ½Ã½ºÅÛÀ» Á¦°ø
* Accurate Infrared CO2 Control System : ºñºÐ»êÇü Àû¿Ü¼± ¼¾¼­·Î ¾ÈÁ¤ÀûÀÌ°í ¸Å¿ì Á¤È®ÇÑCO2 Á¶ÀýÀÌ °¡´É
* Class 100 Air Flow Within the Chamber : HEPA ÇÊÅÍ´Â ¸Å 1ºÐ °£°ÝÀ¸·Î è¹ö ³» °ø±â¸¦ ¿ÏÀü ¼øÈ¯½ÃÄÑ
   Ã¨¹ö ³»ÀÇ °ø±â¸¦ ûÁ¤ »óÅ·ΠÁö¼Ó À¯Áö
* Fast Recovery Time : ºÐ´ç 0.3¡É·Î ¿Âµµ º¸»ó
* Continuous Humidity Supply System
* ºñºÐ»ê Àû¿Ü¼± CO2 ¼¾¼­ ä¿ëÀ¸·Î ¸Å¿ì ¾ÈÁ¤Çϰí ÀæÀº º¸Á¤ÀÌ ÇÊ¿ä ¾ø´Â ÃøÁ¤À¸·Î è¹ö ³» Á¤È® CO2
   Á¶ÀýÀÌ °¡´É
* ±³Ã¼°¡ ¿ëÀÌÇÑ ´ëÇü HEPA ÇÊÅÍ Ä«Æ®¸®Áö´Â ¼øÈ¯ ½Ã °ø±â¸¦ ¿©°úÇÏ¿© è¹ö ³»ºÎ ȯ°æÀ» ûÁ¤À¸·Î À¯Áö
* Fan°ú Blower¸¦ÅëÇÑè¹ö³»ºÎ °ø±â´Â¸Å¿ì´À¸°¼Óµµ·Î±ÕÀÏÇÏ°Ô ¼øÈ¯µÇ¸ç¼¼Æ÷¼ºÀå¿¡¿µÇâÀ»¹ÌÄ¡Áö¾ÊÀ½
* ÀæÀº ¹® ¿©´ÝÀÌ¿¡µµ è¹ö ³»ºÎ´Â ºÐ´ç 0.3¡ÉÀÇ ¼Óµµ·Î ¿Âµµ º¸»óµÇ¸ç, ½Ã·á¿¡ ¿ÂµµÀÇ ¿µÇâÀ» ÃÖ¼ÒÈ­ ÇÔ
* Microprocessor Based, Non-Dispersive Infrared CO2 Sensor is within the Chamber Air Plenum so very
   Accurate CO2 control is achieved.
* The Microprocessor is ¡°User-Friendly¡± with Status Indicators, LED Display of Control Parameters and a
   Touch Control Keypad to permit Efficient Operator entry of Data.
* Directly Heated by Foil Heating Elements attached to the Sides, Bottom, Top and Back of the Chamber
* Constant Air Circulating within the Chamber using a Continuous Operating Fan / Motor / Blower within
   the Upper Air Plenum and Sidewall Duct System
* Continued Air Filtration in the chamber using a Large Replaceable 99.99% Efficient HEPA Filter Cartridge
* The HEPA Filter Uniformly distributes and cleans the Air within the Chamber at a rate of one Complete
   Change per Minute
* Relative Humidity Level up to 95% is achieved in the Incubator by the Use of a Stainless Steel Pan filled
   with Distilled Water and Placed on the Bottom of the Chamber.
* An Air Pump Continuously Introduces Fresh Air into the Chamber at a Variable Rate to Reduce
   Condensation
* Reliable, Accurate, Stable Temperature and Infrared Gas Controls with Quality and Value to meet
   Laboratory Performance for Optimum Growth Conditions
* The Interior Corners of the Growth Chamber are Coved for Ease of Cleaning and to prevent Contaminants
   from becoming Trapped

Accurate Infrared CO2 Control System
* Microprocessor based, non-Dispersive Infrared CO2 Sensor
* The amount of Energy diffused to the Detector is an exact Logarithmic Function of the CO2 Concentration
   in the Gas between Source and Detector.
* The wavelengths are absorbed by a Filter in the CO2 Bandwidth making the Measurements Insensitive
   to other Components, such as Water Vapor.
* Advanced Design provides a very Stable Drift-Free Output requiring less Frequent Calibration.

Ordering Information
N1.5500    CO2 Incubators, Direct Heat Automatic, DH AutoFlow 5500, Air-jacket 188L
    &n
¸ðµ¨ ¹× »ç¾ç
Cat. No. ¸ðµ¨¸í ´Ü À§ °¡ °Ý ¼ö·® ¼± ÅÃ
H11.896.10MC Regulator, 2-stage no.896, co2, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
N1.5500 CO2 Incubator, dh air jacket, 5500, 188l, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ