ºí·ç¶óÀÎ-BL(R) pH Àü±Ø, Glass- / Plastic-Shaft, Compact Basic Series, BNC- / DIN-plug Connections

BlueLine-BL(R) pH / Redox Electrodes, Combination Type

°¡°Ý : °ßÀû°¡
Á¦Á¶»ç : SCHOTT INSTRUMENTS

¸ðµ¨¼±Åà : ÃÑ (7)°³ÀÇ ¸ðµ¨ÀÌ µî·ÏµÇ¾î ÀÖ½À´Ï´Ù.
Àüü¸ðµ¨ ¹× »ç¾çº¸±â

¸ñ·Ïº¸±â
Á¦Ç°»ó¼¼¼³¸í
 Compact Basic Series for the usual Applications : ´Ù¾çÇÑÁ¾·ù, ÀϹÝÀûÀο뵵ÀDZ⺻ÇüÀü±Ø½Ã¸®Áî
* Made from the Universal A-type Membrane Glass
* Comfortable Handling, Stylish Design and Reliable Function
* Liquid Electrolyte Electrodes with Unique Platinum Diaphragm and Refill Port Slider
  ¾ÈÀü∙Æí¸®∙°£´ÜÇÑ¡°Slide-Gate-Hole¡±½ÄÀÇÀüÇØ¾×¡°Electrolyte¡±ÀçÃæÁø¹æ¹ý(Glass Body Àü±Ø°è¿­)
* New Improved Gel-Electrolyte (Plastic Body Àü±Ø °è¿­) : Á¤¹Ð¼º, ±ä ¼ö¸í, ³»¿­¼º Çâ»ó
* Silamid(R) Reference System : Less Interference in the Presence of Disturbance
* Each Electrode with Individual Serial Number
* Platinum(Pt. ¹é±Ý) Diaphragm : ªÀº Set-up ½Ã°£, 25³â ¼ö¸í, ÃÊÁ¤¹Ð¼º
* BNC- & DIN-plug Connections : Meters¿ÍÀÇ ¾çÈ£ÇÑ È£È¯ ¿¬°á¼º
* Plug-cable ºÐ¸®Çü ¹× Plug Type Àüȯ (BNC¸¦ DIN-plug TypeÀ¸·Î)¿ë Adapterµµ ÀÖÀ½.
* The Special Electrodes Range : Surface Measurements, Small Sample Amounts,
   Ultrapure Water and Emulsions or Measurements in Semi-solid Samples
   (Insert Measurements)


¡°SI Analytics¡± pH Glass-shaft Electrodes, BlueLine-BL(R) with Plug-cable, Liquid Electrolyte, 0~14pH, -5~+100¡É
pH Àü±Ø, ±Û¶ó½º-Shaft Àü±Ø, DIN- / BNC-plug Fixed cable(1m) °íÁ¤(ºÎÂø)Çü, ¹é±Ý Diaphragm

* Connection : "DIN-Plug" Type and "BNC-Plug" Type : Àü±Ø / Cable °íÁ¤(ºÎÂø)Çü
* with/without Temperature Sensor (Banana Plug)
* pH Range : 0~14 
* Temperature Range : -5~+100¡É
* Shaft : Glass ¥Õ 12mm, Length L120mm 
* Zero Point : pH=7.0¡¾0.3
* ¹é±Ý(Pt.) Diaphragm 
* 3 mol/l KCl Electrolyte ÀçÃæÁø½Ä ¡°Slide-gate Hole¡±
* Ag/AgCl Reference System 
* Shape of Glass Membrane : Conical
* Type of Membrane Glass A 
* Resistance of Glass Membrane(25¡É), 200MΪ
  ¡Ø ÀÚ¼¼ÇÑ »çÇ×Àº PDFÆÄÀÏ ÂüÁ¶ÇϽñ⠹ٶø´Ï´Ù.

¡°SI Analytics¡± pH Plastic-shaft Electrodes, BlueLine-BL(R) with Plug-cable, Gel Electrolyte, 0~14pH, -5~+80¡É
pH Àü±Ø, ÇÃ¶ó½ºÆ½- shaft Àü±Ø, DIN- / BNC-plug Fixed cable(1m/3m) °íÁ¤(ºÎÂø)Çü, Fibre Diaphragm

* Connection : "DIN-plug" Type and "BNC-plug" Type : Àü±Ø / Cable °íÁ¤(ºÎÂø)Çü 
* with/without Temperature Sensor (Banana Plug)
* pH Range : 0~14 
* Temperature Range : -5~+80¡É 
* Shaft : Noryl ¥Õ12mm, Length L120mm
* Zero Point : pH=7.0¡¾0.3 
* Type of Membrane Glass A 
* Ag/AgCl Reference System
* Resistance of Glass Membrane(25¡É), 400MΪ
  ¡Ø ÀÚ¼¼ÇÑ »çÇ×Àº PDFÆÄÀÏ ÂüÁ¶ÇϽñ⠹ٶø´Ï´Ù.

¡°SI Analytics¡± pH / Redox Glass- Shaft Electrodes, BlueLine-BL(R) with Plug Head, Ag / AgCl Reference System
pH Àü±Ø, Redox ¹× Ư¼ö ±â´É¼º Àü±Ø, ±Û¶ó½º-shaft, Plug-cable ºÐ¸®Çü

* Redox "Rx"¿ë, °úÀÏ/À°·ù µîÀÇ Semi-solid ¿ë, Surface(Ç¥¸é) ÃøÁ¤¿ë, Micro ShaftÇü, ½Å¼Ó/¿¹¹ÎÇü
* Connection : Plug-cable ºÐ¸®Çü : "DIN-plug" Type or "BNC-plug" TypeÀÇ Plug-cableÀ» ¼±Åà »ç¿ëÇÒ ¼ö ÀÖ´Â Æí¸®¼ºÀÌ ÀÖÀ½
* Ag/AgCl Reference System 
* pH Electrode Zero Point : pH=7.0¡¾0.3
* 3 mol/l KCl Electrolyte ÀçÃæÁø½Ä¡°Slide-Gate Hole¡± 
* Type of Membrane Glass A/L
¸ðµ¨ ¹× »ç¾ç
Cat. No. ¸ðµ¨¸í ´Ü À§ °¡ °Ý ¼ö·® ¼± ÅÃ
SG.285129122 Electrode, ph gl, bl12, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
SG.285129147 Electrode, ph gl, bl14, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
SG.285129155 Electrode, ph, bl15, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
SG.285129171 Electrode, ph gl, bl17, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
SG.285129188 Ecectrode, ph, bl18, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
SG.285129440 Electrode, ph gl, bl14-phid, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
SG.285129450 Electrode, ph gl, bl15-phid, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
Äü
¿À´Ãº»»óǰ
Àå¹Ù±¸´Ï
top